Circuit breaker labels for your panel
Build your DIN rail from ABB devices, label every breaker and get an A4 sheet with cut lines for sticker paper: ready-made panel labelling. Free, no sign-up.
- No sign-up
- PDF at 1:1 scale
- Panel saved in the browser
Build the rail from devices
Click devices in the palette: they go onto the rail in order and to scale. The rating is shown on the device itself. Each device will get a label of its own width.
Your panel exactly: rows, the width of every device, ratings. It is saved in the browser automatically.
Fill in the labels
Click the label under a device: an editor with text, icon and colour opens next to it. Common settings apply to all labels at once.
A label under every breaker: as wide as the device, with colour, icon, reference and text. Anything that doesn't fit is marked red.
Get the PDF and print it
A4 landscape sheet: labels in strips by row, cut marks between them, a 100 mm check line at the bottom. Print at 100 % scale on self-adhesive paper.
One PDF file: vector, 1:1 scale, any alphabet. All that's left is to cut the labels along the marks and stick them on.
How to label the breakers in your panel
Labelled breakers save time for the electrician and the homeowner alike: it's clear which circuit feeds what, and you don't have to switch everything off. Here's an order that works in practice.
- Copy the panel as it is
Choose the number of modules per row (12, 18 or 24) and place the devices in the same order as in the panel. Non-standard widths work too: DIN-rail socket, relay, energy meter.
- Name circuits by what they feed
“Kitchen sockets”, “Hall lights”, “Oven”, “Water heater”. The name should make sense to someone opening the panel door for the first time. Check the room and circuit against the diagram.
- Add the reference and rating
References QF1, QF2 or S1, S2 are assigned automatically, as on the panel diagram. The rating comes from the device. That way the label matches the documents, not just the electrician's memory.
- Colour-code the circuits
Lights yellow, sockets blue, stove red, water light blue: the “Colour by purpose” button does it in one click, and you can change the colour of any label by hand.
- Print and check the scale
Print at 100 % on A4 self-adhesive paper. Hold a ruler to the check line: it is 100 mm. Cut the labels along the cut marks.
- Stick them under the devices
Wipe the panel and stick each label centred under its device. Made a typo? Fix it and reprint only that sheet.
Questions about labels
Didn't find an answer? Build the panel in the studio: labelling is built into the project there.
What paper should I print breaker labels on?
Use A4 self-adhesive label paper. For a laser printer, pick paper made for laser printing; for an inkjet, paper made for inkjet. Panels can get warm, so check the temperature rating of the adhesive on the pack.
How do I print to scale so the labels match the devices?
In the print dialog choose 100 % scale and turn off “Fit to page”. Every sheet has a check line: hold a ruler to it, it must be exactly 100 mm. If it is shorter or longer, the printer scaling is off.
How wide are the labels?
A label is as wide as its device: 17.5 mm per module (you can switch to 18 mm in the settings). A two-module breaker gets a 35 mm label, a DIN-rail socket 44 mm. Height is 9, 12, 15 or 18 mm, or your own.
What should I write on a breaker label?
Most important is what the breaker protects: “Kitchen sockets”, “Hall lights”, “Oven”. It helps to add a reference (QF1, QF2 or S1, S2, as on the panel diagram) and the rating. Add the power if you later split circuits across phases by it.
What if a word is too long to fit?
The font size is chosen automatically, and words are never broken in the middle. If even the smallest readable size can't fit a word, the label gets a red dashed outline and a note under the rail tells you what to shorten. A taller label helps too: at 15–18 mm the text comes out larger.
Can I write in another language?
Yes, text prints exactly as typed: any alphabet, digits and symbols. Icons don't depend on language, so the labels are clear to people who read another language too.
Will my work be saved?
The rail and labels are saved in this browser automatically until you clear site data. Nothing is sent to a server. The PDF arrives by email: save it with your panel documents.
Do the devices have to be ABB?
No. The device drawings are ABB, but for labels only the width matters: pick a device with the same number of modules as the one in your panel, and the label will be the right width.
Is it free?
Yes. Labels are made on this page with no sign-up and no payment, and the PDF arrives by email within a minute.
In the studio this happens by itself
- 01References and ratings fill in by themselves
In the studio a device gets its QF, QFD or QD reference in order and its rating from the device card — no typing needed.
- 02The same data goes into the diagram and bill of materials
The single-line diagram, bill of materials and log are built from the same panel: edit in one place.
- 03Labels for tape printers
Wire and core markers export as a file for Brother and DYMO. Device and terminal marking exports as an XLSX table for Phoenix Contact, Weidmüller and ELEGIR.
The studio runs in the browser, nothing to install.



